Human OxLDL (Oxidized low-density lipoprotein) ELISA Kit

Cat# EH0943

Size : 96T

Brand : FineTest

Contact local distributor :


Phone : +1 850 650 7790

Human OxLDL(Oxidized low-density lipoprotein) ELISA Kit

This kit is based on Double antibody-Sandwich ELISA detection method and takes 4h assay time. The microplate provided in this kit has been precoated with anti OxLDL antibody. Add standard and properly diluted sample into relevant well respectively. After incubation, wash unbound components. Add biotinylated detection antibody. Then, it binds with OxLDL bound to precoated antibody. Wash unbound components and add HRP-Streptavidin Conjugate (SABC). Wash unbound components again and add TMB substrate solution. Then, TMB was catalyzed by HRP to produce a blue color product that turned yellow after adding a stop solution. Read the O.D. absorbance at 450nm in a microplate reader. Calculate the concentration of OxLDL in the sample by plotting standard curve. The concentration of the target substance is proportional to the OD450 value.

Catalogue No.: 
EH0943

Alias: 
OxLDL ELISA Kit, Oxidized low-density lipoprotein ELISA Kit

Species: 
Human

Range: 
3.125-200ng/ml

Sensitivity: 
1.875ng/ml

  • SPECIFICATIONS
  • CITATIONS
Product Name
Human OxLDL(Oxidized low-density lipoprotein) ELISA Kit

Alias
OxLDL ELISA Kit, Oxidized low-density lipoprotein ELISA Kit

Catalogue No.
EH0943

Size
48T/96T

Species
Human

Sample Type
Serum, Plasma, Cell Culture Supernatant, cell or tissue lysate, Other liquid samples

Detection Method
Sandwich ELISA, Double Antibody

Detection Wavelength
OD450

Reaction Duration
4 hours

Range
3.125-200ng/ml

Sensitivity
1.875ng/ml

Storage
2-8°C(Sealed), Don't cryopreserve.

Specificity
Specifically binds with OxLDL , no obvious cross reaction with other analogues.

ELISA Kit Components
Kit Components Item Size(48T) Size(96T) Storage Condition for Opened Kit
E001 ELISA Microplate(Dismountable) 8×6 8×12 Put the rest strips into a sealed foil bag with the desiccant. Stored for 1 month at 2-8°C; Stored for 6 month at -20°C
E002 Lyophilized Standard 1vial 2vial Put the rest standards into a desiccant bag. Stored for 1 month at 2-8°C; Stored for 6 month at -20°C
E003 Biotin-labeled Antibody(Concentrated, 100X) 60ul 120ul 2-8°C (Avoid Direct Light)
E034 HRP-Streptavidin Conjugate(SABC, 100X) 60ul 120ul
E024 TMB Substrate 5ml 10ml
E039 Sample Dilution Buffer 10ml 20ml 2-8°C
E040 Antibody Dilution Buffer 5ml 10ml
E049 SABC Dilution Buffer 5ml 10ml
E026 Stop Solution 5ml 10ml
E038 Wash Buffer(Concentrated, 25X) 15ml 30ml
E006 Plate Sealer 3 pieces 5 pieces  
E007 Product Description 1 copy 1 copy

Required Instruments and Reagents
  1. Microplate reader (wavelength: 450nm)
  2. 37°C incubator (CO2 incubator for cell culture is not recommenced.)
  3. Automated plate washer or multi-channel pipette/5ml pipettor (for manual washing purpose)
  4. Precision single (0.5-10μL, 5-50μL, 20-200μL, 200-1000μL) and multi-channel pipette with disposable tips(Calibration is required before use.)
  5. Sterile tubes and Eppendorf tubes with disposable tips
  6. Absorbent paper and loading slot
  7. Deionized or distilled water

Assay Procedure Summary
Elisa实验原理图
  • Step 1: Add 100ul standard or sample into each well, seal the plate and statically incubate for 90 minutes at 37°C.
  • Washing: Wash the plate twice without immersing.
  • Step 2: Add 100ul biotin-antibody working solution, seal the plate and statically incubate for 60 minutes at 37°C.
  • Washing: Wash the plate three times and immerse for 1min each time.
  • Step 3: Add 100ul HRP-Streptavidin Conjugate (SABC) working solution, seal the plate and statically incubate for 30 minutes at 37°C.
  • Washing: Wash the plate five times and immerse for 1min each time.
  • Step 4: Add 90ul TMB substrate solution, seal the plate and statically incubate for 10-20 minutes at 37°C. (Accurate TMB visualization control is required.)
  • Step 5: Add 50ul stop solution. Read at 450nm immediately and calculate.

Standard Curve

This product is detected by QC department and meets performance required in the manual. (Laboratory Humidity: 20%-60%; Temperature: 18°C -25°C; Equilibrate TMB substrate to 37°C before staining. After adding into the ELISA wells, incubate for 15min at 37°C in dark.)

Due to different assay environments and operations, assay data below and standard curve are provided for reference. Experimenters should establish standard curve according to their own assay.

STD.(ng/ml) OD-1 OD-2 Average
0 0.089 0.093 0.091
3.125 0.16 0.169 0.164
6.25 0.198 0.208 0.202
12.5 0.343 0.361 0.35
25 0.487 0.512 0.497
50 0.857 0.901 0.874
100 1.237 1.301 1.263
200 1.968 2.068 2.008
EH0943 Standard Curve Image

Recovery

Add a certain amount of OxLDL into the sample. Calculate the recovery by comparing the measured value with the expected amount of OxLDL in the sample.

Sample Type Recovery Range(%) Average(%)
serum(n=10) 94-102 98
EDTA plasma(n=10) 90-105 95
Heparin plasma(n=10) 89-101 95

Linearity

Dilute the sample with a certain amount of OxLDL at 1:2, 1:4 and 1:8 to get the recovery range.

Sample Type 1:2 1:4 1:8
serum(n=10) 87-101% 90-105% 87-100%
EDTA plasma(n=10) 82-100% 85-98% 83-101%
Heparin plasma(n=10) 84-96% 82-97% 81-99%

Precision(%)

Intra-assay Precision: samples with low, medium and high concentration are tested 20 times on the same plate.

Inter-assay Precision: samples with low, medium and high concentration are tested 20 times on three different plates.

Item Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean (ng/ml) 6.14 23.82 96.04 5.96 24.21 99.66
Standard deviation 0.33 1.2 5.05 0.37 1.55 5.87
CV(%) 5.43 5.02 5.26 6.23 6.42 5.89

Stability

Perform the stability test for the sealed kit at 37°C and 2-8°C and get relevant data.

ELISA kit(n=5) 37°C for 1 month 2-8°C for 6 months
Average(%) 80 95-100

Beneficial Impact of Pork Dry-Cured Ham Consumption on Blood Pressure and Cardiometabolic Markers in Individuals with Cardiovascular Risk
IF: 5.719
Journal:
Nutrients

Cited Date:
2022-01-21

Product:
  • Human OxLDL(Oxidized low-density lipoprotein) ELISA Kit

Comprehensive proteomics of monocytes indicates oxidative imbalance functionally related to inflammatory response in chronic kidney disease-related atherosclerosis
IF: 5
Journal:
Frontiers in Molecular Biosciences

Author:
Department of Biomedical Proteomics, Institute of Bioorganic Chemistry Polish Academy of Sciences, Poznan, Poland

Cited Date:
2024-03-01

Product:
  • Human OxLDL(Oxidized low-density lipoprotein) ELISA Kit

The Effect of Antioxidant Supplementation in Patients with Tinnitus and Normal Hearing or Hearing Loss: A Randomized, Double-Blind, Placebo Controlled Trial
IF: 4.171
Journal:
Nutrients

Cited Date:
2019-12-12

Product:
  • Human OxLDL(Oxidized low-density lipoprotein) ELISA Kit

Selenium-Related Nutritional Status in Patients With Common Variable Immunodeficiency: Association With Oxidative Stress and Atherosclerosis Risk
IF: 3.615
Journal:
BMC Immunology

Cited Date:
2021-02-05

Product:
  • Human OxLDL(Oxidized low-density lipoprotein) ELISA Kit

Selenium levels and glutathione peroxidase activity in patients with ataxia-telangiectasia: association with oxidative stress and lipid status biomarkers
IF: 3.523
Journal:
Orphanet Journal of Rare Diseases

Cited Date:
2021-02-26

Product:
  • Human OxLDL(Oxidized low-density lipoprotein) ELISA Kit

Glycemic, inflammatory and oxidative stress responses to different high-intensity training protocols in type 1 diabetes: A randomized clinical trial
IF: 3.094
Journal:
Journal of Diabetes and its Complications

Cited Date:
2018-09-09

Product:
  • Human OxLDL(Oxidized low-density lipoprotein) ELISA Kit

Journal:
Research Square

Cited Date:
2020-09-11

Product:
  • Human OxLDL(Oxidized low-density lipoprotein) ELISA Kit

Respostas glicêmicas, inflamatórias e de estresse oxidativo em diabéticos tipo 1 submetidos a diferentes protocolos de treinamento de alta intensidade
Journal:
LUME

Cited Date:
2018-11-16

Product:
  • Human OxLDL(Oxidized low-density lipoprotein) ELISA Kit

The Role of oxLDL in Intrauterine Growth Restriction and Its Relationship with Thiol Homeostasis
Journal:
Indian Journal of Forensic Medicine & Toxicology

Cited Date:
2021-07-08

Product:
  • Human OxLDL(Oxidized low-density lipoprotein) ELISA Kit

You might also be interested by the following products:



Cat#
Description
Cond.
Price Bef. VAT
ELH-IL6-1
 1PlateKit