Human HIF-1A (Hypoxia Inducible Factor 1 Alpha) CLIA Kit

Cat# NB-22-40787-1

Size : 96T

Brand : Neo Biotech

Contact local distributor :


Phone : +1 850 650 7790

  • Human HIF-1A (Hypoxia Inducible Factor 1 Alpha) CLIA Kit

General Info

Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 18.75pg/mL
Detection Limit: 31.25~2000pg/mL
Short Description: This human HIF-1A kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence

Information

Specificity: This kit recognizes Human HIF-1 Alpha in samples. No significant cross-reactivity or interference between Human HIF-1 Alpha and analogues was observed.
Sample Type: Serum, plasma and other biological fluids

Description

Specificity This kit recognizes Human HIF-1α in samples. No significant cross-reactivity or interference between Human HIF-1α and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 93-107 100
EDTA plasma(n=8) 87-101 94
Cell culture media(n=8) 85-96 91

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 107.08 299.65 789.01 97.83 321.72 833.58
Standard deviation 10.63 32.51 49.31 9.71 22.55 65.27
CV (%) 9.93 10.85 6.25 9.93 7.01 7.83
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance