Detection Principle Fatty acid oxidation (FAO) is the main pathway of fatty acid decomposition in the body, which can supply a large amount of energy required by the organism. FAO is also the transformation process of fatty acids. The length of fatty acid chain required by the organism is different. Through oxidation, long-chain fatty acids can be transformed into fatty acids with suitable growth degree for the organism metabolism.
The detection principle of this kit: FAO process consumes the substrate and NAD+, and generates NADH. Under the action of electron coupling agent and chromogenesis agent, the orange red substance is generated, which can be detected at 450 nm.
Sample Type Animal tissue, cell
Detection Method Colorimetric method
Detection Instrument Microplate reader(440-460 nm, optimum wavelength: 450 nm)
Research Area Energy Metabolism
Other Reagents Required Normal saline (0.9% NaCl)
Storage This product can be stored at -20°C for 12 months with shading light.
Valid Period 12 months
Sensitivity 0.11 U/L
Detection Range 0.11-8.33 U/L
Precision inter-assay CV: 4.1-5.0% | intra-assay CV: 8.2-9.4%
Sample Volume 100 μL(tissue/cell homogenate)
Assay Time 50 min
Cat.No. Product Name Sizes
E-BC-F002 ATP Chemiluminescence Assay Kit 96T , 48T
E-BC-F068 Oxygen Consumption Rate (OCR) Fluorometric Assay Kit 96T , 48T
E-BC-F069 Extracellular Acidification Rate (ECAR) Fluorometric Assay Kit 96T , 48T

The recommended dilution factor for different samples is as follows (for reference only):

Sample Type Dilution Factor
10% Mouse liver tissue homogenate 2-3
10% Mouse brain tissue homogenate 2-3
10% Mouse lung tissue homogenate 1
10% Mouse spleen tissue homogenate 1
10% Mouse kidney tissue homogenate 2-5
10% Mouse heart tissue homogenate 2-3
10% Mouse muscle tissue homogenate 1
1×10^6 Molt-4 cells 1
1×10^6 HL-60 cells 1
1×10^6 Jurkat cells 1

The diluent is normal saline (0.9% NaCl) or PBS (0.01 M, pH 7.4). For the dilution of other sample types, please do pretest to confirm the dilution factor.

Other Clones

{{antibodyDetailsPage.numTotal}} Results

Other Formats

{{formatDetailsPage.numTotal}} Results

  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.organization}}

detection instrument

{{assayDetailsPage.numTotal}} Results

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

You might also be interested by the following products:



Cat#
Description
Cond.
Price Bef. VAT
ELCR-100
 100Tests