IL-1 alpha High Sensitivity ELISA Kit (Goat)

Cat# OKCD01302

Size : 96Wells

Brand : Aviva Systems Biology

Contact local distributor :


Phone : +1 850 650 7790

Datasheets/ManualsPrintable datasheet for IL-1 alpha High Sensitivity ELISA Kit (Goat) (OKCD01302)
Product Info
Predicted Species ReactivityCapra hircus|Goat
ApplicationEnzyme-linked Immunosorbent assay-Sandwich
ELISA Kit Detection MethodColorimetric
ELISA Kit Duration3h
ELISA Kit Linearity
Sample1:21:41:81:16
Serum (n=5)87-101%82-103%80-97%85-99%
EDTA Plasma (n=5)92-105%78-102%96-105%81-91%
Heparin Plasma (n=5)91-98%80-94%97-105%95-105%
ELISA Kit PrincipleThe test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to High Sensitive Interleukin 1 Alpha (IL1a). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to High Sensitive Interleukin 1 Alpha (IL1a). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain High Sensitive Interleukin 1 Alpha (IL1a), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm +/- 10nm. The concentration of High Sensitive Interleukin 1 Alpha (IL1a) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
ELISA Kit Range0.781-50pg/mL
ELISA Kit Recovery
MatrixRecovery range (%)Average(%)
Serum (n=5)81-9584
EDTA Plasma (n=5)97-104101
Heparin Plasma (n=5)84-10399
ELISA Kit ReproducibilityIntra-assay Precision (Precision within an assay): 3 samples with low, middle and high level High Sensitive Interleukin 1 Alpha (IL1a) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level High Sensitive Interleukin 1 Alpha (IL1a) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
ELISA Kit Component
ComponentAmount
Anti-IL-1 alpha Microplate96 Wells (12 x 8 Well Strips)
IL-1 alpha Lyophilized Standard2
100X Biotinylated IL-1 alpha Detector Antibody120 uL
Avidin/HRP Conjugate120 uL
Standard Diluent1 x 20 mL
Detector Antibody Diluent1 x 12 mL
Conjugate Diluent1 x 12 mL
30X Wash Buffer1 x 20 mL
TMB Substrate1 x 9 mL
Stop Solution1 x 6 mL
Reconstitution and Storage2°C to 8°C|-20°C
Sample TypeSerum, plasma and other biological fluids.
Sensitivity0.32 pg/mL
SpecificityThis assay has high sensitivity and excellent specificity for detection of Interleukin 1 Alpha (IL1a). No significant cross-reactivity or interference between Interleukin 1 Alpha (IL1a) and analogues was observed.
Assay InfoAssay Methodology: Quantitative Sandwich ELISA
Gene SymbolIL-1 ALPHA
Alias SymbolsIL-1 alpha, Interleukin-1 alpha
Protein NameInterleukin-1 alpha
Description of TargetProduced by activated macrophages, IL-1 stimulates thymocyte proliferation by inducing IL-2 release, B-cell maturation and proliferation, and fibroblast growth factor activity. IL-1 proteins are involved in the inflammatory response, being identified as endogenous pyrogens, and are reported to stimulate the release of prostaglandin and collagenase from synovial cells (By similarity).
Uniprot IDP79161
Protein Accession #XP_005686722.2
Nucleotide Accession #XM_005686665.3